  1.        Document 2706
  2.  DOCN  M94A2706
  3.  TI    Field comparison of line-immunoassays with western blot.
  4.  DT    9412
  5.  AU    Maskill W; Tamashiro H; Belsey E; M'Boup S; Wasi C; Liomba G;
  6.        Gershy-Damet G; Fairfield University Melbourne.
  7.  SO    Int Conf AIDS. 1994 Aug 7-12;10(1):243 (abstract no. PB0401). Unique
  8.        Identifier : AIDSLINE ICA10/94369869
  9.  AB    OBJECTIVE: To determine under field conditions the accuracy of
  10.        line-immunoassays (LIA's) for confirming seropositivity for HIV-1 and
  11.        HIV-2 as compared to the Western Blot (WB). METHODS: Sera from four
  12.        countries which were according to WHO WB interpretation criteria
  13.        positive for HIV-1 (n = 650), HIV-2 (n = 35), both HIV-1 and HIV-2 (n =
  14.        63), negative (n = 571) or indeterminate (n = 47) were tested by two
  15.        LIA's (Inno-Lia and Pepti-Lav). Results of the LIA's were interpreted
  16.        according to the criteria provided by the test manufacturers. RESULTS:
  17.        The Inno-Lia and Pepti-Lav tests showed a 98.3% and 98.2% agreement
  18.        respectively with the WB for HIV-1 positive sera. Both LIA's showed 100%
  19.        agreement with the WB for HIV-2 positive sera. Both assays showed
  20.        approximately only a 60% agreement with the WB for sera positive for
  21.        both HIV-1 and HIV-2 with the remaining sera being positive only for
  22.        HIV-1. The LIA's found the majority of WB indeterminate sera to be
  23.        negative, however both tests showed poor specificity due to WB negative
  24.        sera showing indeterminate reactions. DISCUSSION AND CONCLUSION:
  25.        Although the Inno-Lia and Pepti-Lav tests show a high level of agreement
  26.        of WB positive sera, find the majority of WB indeterminate samples
  27.        non-reactive, and produce a lower number of dually reactive sera, both
  28.        assays produce a significant number of indeterminate reactions with WB
  29.        negative sera. The occurrence of these indeterminate reactions may limit
  30.        the ability of these tests to completely replace the WB.
  31.  DE    AIDS Serodiagnosis/*METHODS  *Blotting, Western  Comparative Study
  32.        Human  HIV Antibodies/BLOOD  HIV Seropositivity/*DIAGNOSIS/IMMUNOLOGY
  33.        HIV-1/*IMMUNOLOGY  HIV-2/*IMMUNOLOGY  *Immunoassay  Predictive Value of
  34.        Tests  MEETING ABSTRACT
  35.  